Measuring device for the positioning of tool changer systems

    The alignment is done by a "measuring method" with an exact measuring result.

    • Measuring the offset between tool holder and tool changer in x and z direction as absolute value
    • determination of distance between gripper and spindle
    • easy and safe handling


    Flyer Calibrit


    Application

    Alignment of

    • Magazine to tool changer
    • Pick-up magazine to spindle
    • Tool changer to spindle

    You can measure the axial distance of the contact surfaces / the center offset to the tool spindle and to the tool magazine (transfer of the values to the machine control) / the correction direction and the correction path / various offset tolerances.



    2 Components - 1 Unit

    One component is the measuring unit (dial gauge) for determining and displaying the center offset and the axial distance by means of a direction pointer.
    The correction dimension must be set.

    The second component is the test fixture in common ISO standards.







    1. insert test fixture          2. insert measuring unit          3. bring components together          4. apply stylus and measure



    Please select the desired interface:


    ISO7388-1 | DIN69871 (SK)

     CA-SK30 CA-SK40 CA-SK50
    ISO7388-2 | JIS B 6339 (MAS BT)

     CA-BT30 CA-BT40 CA-BT50
    ANSI B5.50 (CAT)

     CA-CAT40 CA-CAT50
    ISO12164 | DIN69893 (HSK)

     CA-HSK40A/40E/40T CA-HSK50B/50F CA-HSK63B/63F
     CA-HSK50A/50E/50T CA-HSK63A/63E/63T CA-HSK100A/100E/100T
    ISO26623-1 (PSC)

     CA-C4 CA-C6 CA-C8X
     CA-C5 CA-C8


    Flyer Calibrit

    >>Calibrit  >> Calibrit easy   >>Calibrit easy2.0
    Banner Calibrit WSW

    Alignment device Calibrit Easy

      The alignment is done via a "probing procedure" with an "okay" / "not okay" result.

      • Measuring the offset between tool holder and tool changer in x and z direction as absolute value
      • determination of distance between gripper and spindle
      • easy and safe handling

      with the Calibrit Easy2.0 aligment device, it is also possible to:

      • determine the angular position (position of the groove in the spindle to the position of the groove in the gripper groove


      Application

      Alignment of

      • Alignment of tool changer with gripper arm to chain or disc magazine
      • Alignment of chain or disc magazine to tool spindle
      • Alignment of transfer unit or swivel unit to chain or disc magazine



      3 Components - 1 Unit

      The Calibrit Easy aligment device consists of a spindle cone (1), a gripper disc (2) and a staking pin (3).







      1. insert test fixture          2. insert measuring unit          3. bring components together          4. stake out bolt

      Please select the desired interface:


      Flyer Calibrit
      ISO7388-1 | DIN69871 (SK)

       CA Easy-SK30 CA Easy-SK40 CA Easy-SK50
      ISO7388-2 | JIS B 6339 (MAS BT)

       CA-Easy BT30
      ISO12164 | DIN69893 (HSK)

       CA Easy-HSK40A/40E/40T CA Easy-HSK80B/80F CA Easy-HSK200A/200E/200T
       CA Easy-HSK63A/63E/63T CA Easy-HSK100A/100E/100T
       CA Easy-HSK80A/80E/80T CA Easy-HSK125A/125E/125T
      ISO26623-1 (PSC)

       CA Easy-C6



      >>Calibrit   >> Calibrit easy    >>Calibrit easy2.0
      Banner Calibrit WSW

      Alignment device Calibrit Easy

        The alignment is done via a "probing procedure" with an "okay" / "not okay" result.

        • Measuring the offset between tool holder and tool changer in x and z direction as absolute value
        • determination of distance between gripper and spindle
        • determine the angular position (position of the groove in the spindle to the position of the groove in the gripper groove
        • easy and safe handling


        Application

        Alignment of

        • Alignment of tool changer with gripper arm to chain or disc magazine
        • Alignment of chain or disc magazine to tool spindle
        • Alignment of transfer unit or swivel unit to chain or disc magazine



        4 Components - 1 Unit

        The Calibrit Easy aligment device consists of a spindle cone (1), a gripper disc (2), a staking pin (3) and a positioning pin (4) for determining the angular position.





        Please select the desired interface:


        ISO7388-1 | DIN69871 (SK)

         CA Easy2.0-SK30 CA Easy2.0-SK40 CA Easy2.0-SK50
        ISO7388-2 | JIS B 6339 (MAS BT)

         CA-Easy2.0 BT30 CA-Easy2.0 BT40 CA-Easy2.0 BT50
        ISO12164 | DIN69893 (HSK)

         CA Easy2.0-HSK40A/40E/40T CA Easy2.0-HSK50B/50F CA Easy2.0-HSK63B/63F
         CA Easy2.0-HSK50A/50E/50T CA Easy2.0-HSK63A/63E/63T CA Easy2.0-HSK100A/100E/100T
        ISO26623-1 (PSC)

         CA Easy2.0-C4 CA Easy2.0-C6 CA Easy2.0-C8X
         CA Easy2.0-C5 CA Easy2.0-C8


        Flyer Calibrit
        | Where you can find us
        | Address
        WSW Spannwerkzeuge-Vertriebs GmbH
        Maybachstrasse 1
        73066 Uhingen
        Germany
        Scan me WSW
        © Copyright 2022 WSW Spannwerkzeuge Vertriebs GmbH. All rights reserved.
        Back to content